Industrial Wireless Controls
Microprocessor controlled with smart functions. Reliable, simple
and easy to install
|
1 mile (2 km)
line of sight, • 1000. feet (300 m)
obstructed. 2 miles (3 km)
line-of-sight with ex
antenna 7099 |
|
Series 931000 |
TRANSMITTER |
RECEIVER |

(1) Single channel |

|

|
| |
|
|

(2) Two channel |
|

|
| |
|
|

(4) Four channel |

|

|
|
Specifications Digital Transmitter
|
|
Supply power |
12 VDC
SOLAR READY |
|
Operating Current |
Standby 0.01 mA, Transmission 400 mA |
|
Inputs |
N/O Normally
Open, digital dry contact |
|
Transmitter power |
per
FCC Part 15.249,
50mV/m @ 3m |
|
Transmission |
Digital Encoded
frequency-shift_keying |
|
Channels |
4096 addresses per system
|
|
Connection |
Screw Terminal |
|
Response |
500 msec
|
|
Weight |
1.2 lb (0.70kg)
each unit |
|
Dimensions |
11.81 x 7.87 x 6.29 in.
299.97 x
199.90 x 159.77 mm |
|
Temperature |
4° to
140° F (-10° to 60° C) |
|
Ambient RH |
5% to 95% RH non condensing |
| |
Antenna
selection |
|
|
Specifications Digital Receiver
|
| Supply power |
12 VDC |
|
Operating
Current |
Standby
20 mA, Energized 70 mA |
| Frequency |
27 MHz
•
License free Industrial |
| Setup |
DIP switch mode |
| Outputs |
Relay contact 5A
N/O- N/C 240VAC |
| Output Mode |
Momentary, Toggle,
Off delay |
| Off Delay
Output |
Adjustable up to 10 minutes |
|
Configuration |
FCC CFR part 15.247 |
| Enclosure |
NEMA 3R Non
Metallic Enclosure |
Output selection
|
ACTION |
Transmitter
: Receiver |
|
Momentary: |
Close switch: Turn ON, After
4 seconds Turn OFF |
|
Toggle/Latch: |
Pulse sw:
Turn ON, Pulse switch again Turn OFF |
|
Time interval: |
Close switch:
Turn ON, Off delay up to 10 minutes |
|
|
|
 |
931081 Supervised Kit
ONE Base Transmitter dry N/O contact input
ONE
Base Receiver with supervised module
TWO Antennas with coaxial
cable & PL259
NEMA 4, IP67 non metallic enclosure,
Output:
10 Amp max. 250VAC
N/O and N/C
Application:
Pump Control, Security |
|
931081 Supervised Single
Channel Wireless System
|
ACTION |
Transmitter
: Receiver |
|
Input Dry Contact |
Close switch: Turn ON,
Switch
Opens Turns OFF |
|
Supervised module |
Checks the
system every 10 minutes for
operation status; On carrier,
on power loss or tampering, the system will
Turn OFF the receiver,
Automatic security
disconnect
|
|
Specifications |
Applications:
Field
control operations,
irrigation, lighting, parks, gates, remote power generators,
solar systems, water pumps, remote monitoring, mobile applications,
marinas, perimeter early warning, security, traffic control,
sport arenas, racing tracks, military installations, building
automation, windmills, area lighting, etc.