						 Industrial Wireless Radio Controls 
 
  Please 
					Request latest price
 
						
				
					| 
			  
							
							Performance
 •
							5 miles ( 8 km) 
			line-of-sight w Omni antenna
 • Extended range up to 20 km
 • Operation:  120/240VAC 
						or 12VDC
 • 
									Transmitter input N/O Dry contact
 •
			Receiver with signal strength indicator
 • Relay Output SPDT, 6A Class 2 pilot duty
 • 
									Heavy Duty NEMA4, IP65 UL Fiber enclosure
 • License free 154MHz Industrial 
						MURS band
 • Factory configured systems, Ready to operate
 • No setup or programming required
 
							
								■
					Complete 
							system:
 One Transmitter 2 Ch in NEM4 Enclosure
 One Receiver 
								in NEM4 Enclosure
 Two Omni Antennas 931487  Antenna Selection
 
						■
					
					
					Operation: 
						Example
 
 ■ If Low 
						Level SW Close: ,  Pump Start.
 ■  
			If 
						High Level SW Close: ,  Pump 
						Stop.
 
 
 System 
			with High and Low Indicators
 
 
  |    
						
							
								|  DISCLAIMER: Radio control equipment 
		in not to be used in life safety.
 Radio Installations shall be 
		performed by a certified professional.
 |  
												  |  | Remote 
					operation for: 
														Pumps, Lighting, 
														Process, Alarms, 
														Gates, Valves. 
 
						
                                
                                
                                | ■
						Applications: 
 Industrial Monitoring, Pump control, Monitor remote 
			sites, Tank Level,
 Lighting control, Remote Mobile system, PLC remote, SCADA, 
			Gates.
 Factory process control,  Alarms, Generators,  
														Solar,  Wire replacement.
 
 |  
                                | 
              
                | Supply power | 120/240VAC or 
									12VDC /  8watt |  
                | Inputs | N/O Normally 
				Open, digital dry contact |  
                | Transmitter power | per 
				FCC Part 15.249,  
				50mV/m @ 3m |  
                | Transmission | Digital Encoded 
				
				Gaussian_frequency-shift_keying |  
                | Channels | 16 addresses per system 
				GFSK |  
                | Power Consumption | Standby 1mA, 
				Transmission Pulse 1200mA  Solar Ready |  
                | Response | Loop 500 msec |  
                | Weight | 6.8 lb (3.40kg)  
				each unit |  
                | (*) Dimensions | 12"W x 
										10"H x 
				6"D (300 x 250 x 150 mm) |  
 
				
					
						| Specifications      Digital Receiver |  
              (*) Final Component layout and Dimension may vary
                | Supply power | 120/240VAC or 
									12VDC /  5watt |  
                | Output | Relay 20Amp, SPDT Class 2 pilot duty |  
                | Frequency | 154MHz  •
										License free MURS band |  
                | Configuration | DIP switch factory 
				preset |  
                | Compliance | FCC CFR part 15.247, 95 sub E |  
                | Wiring | Screw Terminals |  
                | Antenna Z | 50 Ohm |  
                | Ambient temp | 14° to 140° F (-10° to 60°
                  C) |  
                | Enclosure | NEMA4, IP65 |  
   |  
 
							
							              Typical 
					wiring application example
 
      				  |